Ethical Guidelines

University of Illinois trained engineers are the best and most highly sought in the world. Our graduates are superbly trained, highly competent, and creative. This, however, is not enough. Our engineers must also be trusted to conduct themselves according to the highest ethical standards. All teams must address ethical considerations in their projects. This requirement has two parts.

First, there is a stringent Code of Ethics published by professional societies, such as IEEE and ACM. The power of these Codes of Ethics is to provide guidance to engineers in decision making and to lend the weight of the collective community of engineers to individuals taking a stand on ethical issues. Thus the Code of Ethics both limits the professional engineer and empowers the professional engineer to stand firm on fundamental ethical bedrock. All teams must read the IEEE code and ACM code and comment on any sections of the code that bear directly on the project.

Second, we expect our students to have personal standards of conduct consistent with the IEEE and ACM Codes of Ethics, but also beyond it. That is, there are areas of ethics not addressed by these Codes that the engineer may consider in taking on projects or jobs or making other professional decisions. These are personal standards and choices. In the context of the class, there are no right or wrong answers here. Our students simply need to demonstrate that they are thinking deeply about their own decisions and the consequences of those decisions. We encourage our students to consider the wider impact of their projects and address any concerns raised by potential uses of the project. Students should ask themselves, "Would I be comfortable having my name widely attached to this project? Do I want to live in a society where this product is available or widely used? Would I be proud of a career dominated by the decision making demonstrated here?" Remember that UIUC engineers have a long history of inventions that really has changed the world.

If the students feel that these Codes of Ethics does not directly bear on their project and that there are no other reasonable concerns, they should not invent issues where there are none. Students will still be expected to be familiar with the IEEE Code of Ethics and ACM Code of Ethics.

Recovery-Monitoring Knee Brace

Dong Hyun Lee, Jong Yoon Lee, Dennis Ryu

Featured Project

Problem:

Thanks to modern technology, it is easy to encounter a wide variety of wearable fitness devices such as Fitbit and Apple Watch in the market. Such devices are designed for average consumers who wish to track their lifestyle by counting steps or measuring heartbeats. However, it is rare to find a product for the actual patients who require both the real-time monitoring of a wearable device and the hard protection of a brace.

Personally, one of our teammates ruptured his front knee ACL and received reconstruction surgery a few years ago. After ACL surgery, it is common to wear a knee brace for about two to three months for protection from outside impacts, fast recovery, and restriction of movement. For a patient who is situated in rehabilitation after surgery, knee protection is an imperative recovery stage, but is often overlooked. One cannot deny that such a brace is also cumbersome to put on in the first place.

--------

Solution:

Our group aims to make a wearable device for people who require a knee brace by adding a health monitoring system onto an existing knee brace. The fundamental purpose is to protect the knee, but by adding a monitoring system we want to provide data and a platform for both doctor and patients so they can easily check the current status/progress of the injury.

---------

Audience:

1) Average person with leg problems

2) Athletes with leg injuries

3) Elderly people with discomforts

-----------

Equipment:

Temperature sensors : perhaps in the form of electrodes, they will be used to measure the temperature of the swelling of the knee, which will indicate if recovery is going smoothly.

Pressure sensors : they will be calibrated such that a certain threshold of force must be applied by the brace to the leg. A snug fit is required for the brace to fulfill its job.

EMG circuit : we plan on constructing an EMG circuit based on op-amps, resistors, and capacitors. This will be the circuit that is intended for doctors, as it will detect muscle movement.

Development board: our main board will transmit the data from each of the sensors to a mobile interface via. Bluetooth. The user will be notified when the pressure sensors are not tight enough. For our purposes, the battery on the development will suffice, and we will not need additional dry cells.

The data will be transmitted to a mobile system, where it would also remind the user to wear the brace if taken off. To make sure the brace has a secure enough fit, pressure sensors will be calibrated to determine accordingly. We want to emphasize the hardware circuits that will be supplemented onto the leg brace.

We want to emphasize on the hardware circuit portion this brace contains. We have tested the temperature and pressure resistors on a breadboard by soldering them to resistors, and confirmed they work as intended by checking with a multimeter.

Project Videos